Jiangsu Acrel Electrical Manufacturing Co., LTD.

AMC72L-AV3 Three Phase AC Voltage Meter

•Communication:RS485 (Modbus-RTU)

•Display:LCD display, set multiplying power

•Rated U:AC voltage: AC 100V, 220V, 380V

General

AMC series AC ammeter&voltmeter, adopting AC sampling technology, can directly measure current and voltage of three phase grid. It can be used for local display, and connecting industrial control device to form measuring control system.

Parameters

Communication

RS485(Modbus-RTU)

Display

LCD display, set multiplying power

Rated U 

AC voltage: AC100V, 220V, 380V

Frequency

Range: 45-65Hz

Consumption

Power consumption of each voltage, current input circuit is less than 0.5VA

Accuracy

Class 0.5

 

Installation

Panel mounted

Dimension(L*W*H)

Panel size (L×W): 75*75mm
Cutout (L×W): 67*67mm
Housing (L×W×H): 66*66*94.3mm
Auxiliary power supply
Voltage range: AC220V

Power consumption: <5VA

Relay

3A/30V DC, 3A/250V AC

Technical Datasheet

Technical Parameter Value
Input Rated Value AC voltage:Single phaseAC 100V,400V

Three phaseAC 100V,400V,660V(UL-L,Only 72/ 96)

Overload Voltage: 1.2 times rated value(continuous); 2 times rated value /1 second

Current:1.2 times rated value(continuous); 10 times rated value /1 second

Frequency 45Hz~65Hz
Power Consumption Power consumption of each voltage,current input circuit is less than 0.5VA
Accuracy Class 0.5
Function Display LED or LCD
Communication RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)

Baud Rate 2400/4800/9600/19200 bps etc.

Alarm 1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc.
Analog DC4~20mA,( load <500Ω)

(note:Shielded wire is specially selected for the above signal input and output)

Switching Input:4 channel or 2 channel dry contact Input,built in power supply

Output:2 channel switching output,NO relay contact,capacity:3A/30VDC,3A/250VAC

Auxiliary Supply AC/DC 85-265V
Power Consumption <5VA
Insulation resistance ≥ 100MΩ
Power frequency withstand voltage Between power supply set of terminals and signal input,output set of terminals 2kV/1min (RMS)

Between the shell and all set of terminals(except the set of terminals reference voltage less than 40V) AC 4kV

 

Environment

Temperature Operation: -10℃~+55℃Storage: -25°C ~+70°C
Humidity ≤95%RH,no condensation,without corrosive gas
Altitude ≤ 2500m

 

Dimension

Wiring

Network

Installation

 

1. Cut out a hole on the object on where we will intall the meter according to dimension of meter referred above.

2. Remove the buckle on the meter off.

3. Install the meter into the cut-out hole.

4. Buckle up and fixed the meter.

FAQ

Q: No display on power?

A: Check whether the supply voltage is within the operating voltage range.

Q: Incorrect reading of voltage,current,electricty,etc?

A: Checking that the voltage/current ratio setting are correct;

Checking whether the wiring mode setting is consistent with the actual situation;

Checking whether the voltage transformer and current transformer are in good condition.

Q: Abnormal communication?

A: Check whether the adress,baud rate,check bits in the communication;

Setting are consistent with the host computer;

Check whether the RS485 converter is normal;

Check the connection is corrent if the resistor above 120 ohm is connected in parallel at the communication end.

Package

MINIMUM PACKAGE
MINIMUM PAKAGE Package dimensions(1 PC)

230*145*120mm

Pakage Weight(2 PC)

0.5Kg

WHOLE BOX PAKAGE Package dimensions(48 PCS)

615*480*395mm

Pakage Weight(36 PCS)

12kG

PRODUCT HS CODE 9028301400

 

ATTENTION !

The above packing and weight data are only refer to model AMC72L-AV3.

For other models or optional functions, please contact the salesman for details, thank you for your cooperation!

Related Products

Inquiry Now

Would you like to get information about Acrel? We appreciate your interest and would be happy to advise you.Simply give us some information so we can get in touch with you

Contact us

We will contact you within 24 hours.

弹窗表单