Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

  • Full electric parameter measurement,Multi Channels independent metering
  • With Different Size of CTs,easy to install D10,D16,D24,D36
  • RS485 standard, Optional 4G Ethernet or WIFI
  • Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring
  • Application: for the Multi channels places

Parameter

ADW600-U Rated voltage 3×57.7/100V, 3×220/380V, 3×100V, 3×380V
Voltage accuracy 0.5%
Reference frequency 45-65 Hz
Power consumption <0.5VA per phase
ADW600-I Input Current D10:0.03-0.15(6)A, D16:0.8-2(100)A, D24:3.2-8(400)A, D36: 4.8-12(600)A
Active energy accuracy Class B
Energy pulse width 80±20ms
Active pulse constant D10: 6400 imp/kWh , D16: 400 imp/kWh , D24: 100 imp/kWh , D36: 60 imp/kWh
Power consumption <1VA per phase
ADW600-K Switch input 4-way passive input, built-in DC12V power supply
Switching output 2-way passive output, capacity AC230V/DC30V, 3A
ADW600-TL Temperature measurement 12-channel temperature measurement, accuracy ±2°C, 12 temperature measurement lines as standard
Residual current measurement 4-way residual current measurement, input maximum 1mA, accuracy 1%, residual current transformer needs to be purchased separately

 

Temperature range Operating temperature -25 ℃ ~ 55 ℃​
Storage temperature -40 ℃ ~ 70 ℃​
humidity ≤95% (no condensation)
altitude <2000m

Dimension

  1. The ADW600-M gateway (-4G/-CE/-WF) on the far left of the ADW600 rendering in Figure 1 needs to be ordered separately.
  2. When connecting network cables between different modules, please note that BUS-IN is the incoming interface and BUS-OUT is the outgoing interface. Start with ADW600-M or the power module and connect them in sequence. Do not connect them in reverse.

Specifications: Model Overall dimensions (mm) Perforation size (mm) Tolerance (mm)
W H D M N Φ1 Φ2
D10:AKH-0.66/K- ∅10N 27 44 32 25 36 10 9 ±1
D16:AKH-0.66/K-∅16N 31 50 36 27 42 16 17
D24:AKH-0.66/K-∅24N 39 71 46 36 52 24 23.5
D36:AKH-0.66/K-∅36N 42.5 82 58 40 56 33.5 35

Wiring

ADW600 multi-circuit metering modules are connected by network cables. BUS-IN is the incoming interface and BUS-OUT is the outgoing interface. They are connected starting from ADW600-M or the power module and cannot be connected in reverse.

ADW600 -U needs to be connected to the load voltage signal. Refer to the wiring diagram below. Terminals 11-14 are connected to the UA, UB, UC, and UN voltage signals respectively. If the three-phase three-wire connection method is used, terminals 11-13 are connected to the UA, UB, and UC voltage signals, and then UB is short-circuited into the UN terminal.

ADW600 -I needs to be connected to the load current signal. Refer to the wiring diagram below. The standard transformer is an RJ12 interface that can be inserted into the meter terminal. The three transformers can be clipped onto the load cables according to the indicated directions.

ADW600 -K is connected to the switch input or output signal line as needed. Note that the COM port is the common end. Refer to the wiring diagram below.

ADW600 -TL is connected to the temperature measurement signal line or the residual current transformer signal line as needed. Note that the COM port is the common end of the adjacent measurement circuits. The specific wiring diagram is as follows.