Jiangsu Acrel is located in Jiangyin City, Jiangsu Province. Since it was officially put into operation in 2006, it has a total of more than 700 employees, including 400+ technicians with a bachelor degree or above, accounting for 60% of the total number of employees. The modern production plant covers an area of 60,000 square meters. At present, there are 8 automatic placement (SMT) assembly lines, 10 semi-automatic electronic assembly lines, 5 complete machine production lines, 3 power sensor production lines, 4 non-standard low-voltage complete electrical equipment production lines, and annual production of power meters/measurement and control devices 3.5 million sets, 2 million power sensors, and 10,000 sets of non-standard electrical cabinets.

Our Products

Data Center / Tower / Base Station

ATU Intelligent Monitoring Terminal for Switchgear

  • Collect the operation data of the switch cabinet, enabling centralized monitoring and management, and uploading the data to the monitoring system for the maintenance personnel to refer to.
  • Achieve one-click sequential control conversion operations for the “operation – hot standby – cold standby – maintenance” four states in coordination with various devices.
  • Unctions such as pre-prepared operation tickets, automatic execution of operation ticket sequences, and anti-misoperation verification.
  • Lremote control functions for circuit breakers, pressure plates, and handles, and has anti-misoperation double verification.
  • L2 Ethernet interfaces and 6 RS485 serial ports.
  • Supports Mod Bus-RTU, Mod Bus-TCP protocols, and IEC60870-5-104 protocol.
  • Supports a graphical interface and can simultaneously adjust about 200 inverter groups.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

  • Channel: 6 channel 3 phase or 18 channel 1 phase :
  • Rated Voltage: AC 3×220V/380V
  • Accurancy: Voltage and current level 0.5, active energy level 1
  • RS485(MODBUS-RTU)
  • Opening size: 88*88mm

Acrel AMC16-DETT Multi-Circuits DC Energy Meter

  • DC rated voltage: 1 channel: -48VDC
  • Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
  • RS485(MODBUS-RTU)
  • DIN 35 mm
  • Designed for base stations

Acrel AMC200L-8E3/4G Smart Digital Multi-Circuit AC Electricity Meter

  • Funtion:full power parameter measurement, Active 2DI+Passive 4DI+2DO, 4 NTC Temperature, 1T&H
  • Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
  • RS485(Modbus RTU protocol), 4G
  • Power supply: AC/DC 85-265V
  • Applicaiton: telecom Base station,other multi channels applicaiton

AMC200L-12DE DC Multi-Channel Power Meter For Tower Base Station Power Monitor

  • Measurement: 3-phase U, I, P and etc
  • Frequency: Voltage,Current Class 0.5,Power Class 1.0
  • Rated Voltage: DC -48V
  • Rated Current: 12 Channels Hall Current Sensor:Hall sensor secondary side DC 5V access
  • Communication: RS485 (MODBUS-RTU), 4G
  • Function: 6DI/2DO, 2 NTC, 1T&H
  • Power supply: DC-40V~-60V

DTSD1352-4S Multi-circuit Energy Meter for Tower Base Stations

● Mearsure up to 4 circuit 3 phase

● Mearsure all electric parameters
● Split core open loop CTs

● LCD Display

Smart Busway monitoring solution

real-time monitor energy consumption and power quality of end load in smart track busway

Data can be uploaded to monitoring system

monitor real-time temperature at the busway connector

PDI’s Branch Circuit Monitoring System BCM

real-time monitor and centralize power consumption in data center

data can be displayed on HMI

uploaded to the power and environment monitoring system by RS485

realize real-time monitoring of whole power distribution system

Energy Consumption Monitoring for Base Station

measure energy in AC side of tower base station

In DC side monitor electrical parameters

measure energy such as base station communication device, battery and other devices

working under -48V power supply

AMC16Z-FAK48 Multi channel din rail ac power meter

  • ● Designed specifically for the power supply management of server in the data center

    ● A+B independent 24 circuits(48 in total)

    ● U, I, P, Q, S, PF, kWh, kvarh

    ● 2nd-31st  Harmonic

    ● kWh Class 0.5

    ● DIN 35 mm

AMC16Z-FDK24/48 DC multi circuits energy meter

  • Designed specifically for the power supply management of server in the data center
  • A+B independent 24 circuits(48 in total)
  • U, I, P, Q, S, PF, kWh, kvarh
  • 2nd-31st  Harmonic
  • kWh Class 0.5
  • DIN 35 mm

AMC16Z-ZA AC multi channel energy meter

● Designed specifically for the power supply management of server in the data center
● A+B independent 2 channels three-phase inlet
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-63rd  Harmonic